66 CHAPTER 6 SENSOR SETTINGS
Source – In normal use, the source is always the radar antenna. However, in some
cases, other sources may be used for demonstrations or evaluations. When the source
is switched to Diagnostic, the antenna is no longer used. Instead, a predetermined
sequence of trac will appear.
Advanced Tab
e Advanced tab contains higher-level features that will not typically need to be adjusted
by normal users (see Figure 6.3).
Figure 6.3 – Advanced Tab
Wash-out time – Used to set the amount of time a tracker has to be detected before it
is washed out into the background. Range of valid values: 4-60 minutes.
Use Weather Optimizations – is setting will only need to be used if you are install-
ing a sensor in an area with heavy rain or snow. Consult Wavetronix Technical Services
before using this setting.
Blind Sensor Triggers Failsafe – is checkbox will activate aer checking the Use
Weather Optimization checkbox and should only be used if the sensor is being in-
stalled in an area with extreme winter weather conditions. Consult Wavetronix Techni-
cal Services before changing this setting.
Queue Forming – is setting is used to ll in the gaps between the cars in a queue. We
recommend that this setting remains checked. Consult Wavetronix Technical Services
before changing this setting.
Presence Update Time – is setting allows you to control how oen the sensor push-
es data. Consult Wavetronix Technical Services before changing this setting.