APPENDIX 103
during the threading process, connect the plug and coupling ring to a sensor connec-
tor receptacle.
9 Press all of the connector parts together. read the strain relief onto the back shell.
10 Tighten the strain relief screws on the back.
Figure A.2 – Connector Sub-assembly Parts
Appendix B – Cable Lengths
It is recommended that the sensor be powered by 24 VDC to achieve reliable operation up
to 500 . (152.4 m) away. Table B.1 lists maximum cable lengths for 12 and 24 VDC.
Power Wire Gauge 24 Volts 12 Volts
20 AWG 500 ft. (152.4 m) 90 ft. (27.4 m)
Table B.1 – Maximum Cable Length for Power (ft)
For communications, both of the sensor’s RS-485 communication ports operate at 9600
bps.
Note
Contact Wavetronix Technical Services if you have a need for a cabled connection over
500 ft. (152.4 m).
Appendix C – Click 221 User Reference Guide
e Click 221 is a DC 8 A surge protector (8 A is the maximum rating of a T-bus connec-
tor). e DC source voltage and PE (protective earth) should be wired into the screw ter-
minals on the bottom side of the device. A 12 AWG protective earth wire is recommended.
e device works with up to 8 A of continuous current at a maximum of 28 VDC.