CHAPTER 5  COMMUNICATION 57
Figure 5.6 – Internet Connection Screen
3 Enter the IP address or URL of the sensor of interest. Enter the IP address assigned to
either the CDMA modem or the Click 301 serial to Ethernet converter.
4 Enter the port number assigned to the CDMA modem or the Click 301 serial to Eth-
ernet converter in the Port eld. is will be an integer value in the range of 0–65536.
e Click 301 port number automatically defaults to 10001.
5 Set the Timeout value to 1000.
6 Select the type of search (Full or Quick) you would like to perform (see the Serial
Connection section of this chapter for more on these two searches).
7 Click the Search button. is may take up to 30 seconds while the sensors on your
control bus are discovered and listed. (You can click Cancel as soon as the sensor of
interest is listed.)
8 Click on the desired row from the list to select a sensor (see Figure 5.7).
Figure 5.7 – Internet Connection Screen