APPENDIX 105
receptacle.
9 Press all of the connector parts together. read the strain relief onto the back shell.
10 Tighten the strain relief screws on the back.
Figure A.2 – Connector Sub-assembly Parts
Appendix B – Cable Lengths
It is recommended that the sensor be powered by 24 VDC to achieve reliable operation
up to 500 ft. (152.4 m) away. Table B.1 lists maximum cable lengths for 12 and 24 VDC.
Power Wire Gauge 24 Volts 12 Volts
20 AWG 500 ft. (152.4 m) 90 ft. (27.4 m)
Table B.1 – Maximum Cable Length for Power (ft)
For communications, both of the sensors RS-485 communication ports operate at 9600
bps.
Note
Contact Wavetronix Technical Services if you have a need for a cabled connection
over 500 ft. (152.4 m).
Appendix C – Click 221 User Reference Guide
e Click 221 is a DC 8 A surge protector (8 A is the maximum rating of a T-bus connec-
tor). e DC source voltage and PE (protective earth) should be wired into the screw ter-
minals on the bottom side of the device. A 12 AWG protective earth wire is recommended.
e device works with up to 8 A of continuous current at a maximum of 28 VDC.